Lab Tip #8

Lab Tip #8: What Is Water Activity?

Lab Tip #8: What is water activity?0:23 Watch on YouTube

Two products with the same moisture content can spoil at very different rates. The value that explains this is water activity (aw). Here we look at what water activity is, how it differs from moisture and how it is measured.

Contents4 sections
  1. What is water activity?
  2. Are moisture and water activity the same?
  3. Microorganisms and aw
  4. How is water activity measured?

What is water activity?

Water activity (aw) shows, on a scale of 0 to 1, how much of the water in a product is available to microorganisms. Pure water has an aw of 1. As salt, sugar or drying “binds” part of the water, aw falls. Water activity is decisive for microbial spoilage, shelf life and texture stability.

Are moisture and water activity the same?

No. Moisture (water content) is the total amount of water in a product and is measured with a moisture analyser. Water activity shows how much of that water is “free” for microorganisms and chemical reactions. So a jam and a cake with the same moisture content can have very different water activity and shelf life. The two measurements complement each other.

Microorganisms and aw

Each group of microorganisms has a lower aw limit for growth. According to approximate values widely accepted in the literature:

  • Most bacteria grow above about 0.90.
  • Most yeasts grow above about 0.88.
  • Most moulds grow above about 0.80.
  • Below about 0.60, microbial growth generally stops.

That is why aw is one of the main measurements that set the shelf life of dry and intermediate-moisture products. Values vary with species and conditions; use your own specifications for the limits that apply to your product.

How is water activity measured?

Steroglass aWLife is a water activity meter that measures the aw of a sample directly in the laboratory with a dew point sensor:

  • A measurement takes about 5 minutes, with an accuracy of ±0.003 aw at 25 °C.
  • Sample temperature can be set between 15 and 50 °C and programmed for shelf-life studies.
  • It has a 7-inch colour touch screen, automatic data storage and USB or Ethernet connection to PCs, printers and barcode readers.
  • Single or multi-point calibration is possible; the measuring method can be accredited to ISO 18787:2017.

For installation and training, contact us. You will find the other posts of the Lotus Analitik lab tips series below.

Lab Tips

More from this series

All articles
  1. Lab Tip #1Lab Tip #1: How to Make the First Dilution
  2. Lab Tip #2Lab Tip #2: Why Is There Salt in Dilution Fluid?
  3. Lab Tip #3Lab Tip #3: How Should Hygiene Swabs Be Stored?
  4. Lab Tip #4Lab Tip #4: How Should Easy Plate Be Stored?
  5. Lab Tip #5Lab Tip #5: Is Measuring ATP Alone Enough?
  6. Lab Tip #6Lab Tip #6: When Should Frying Oil Be Changed?
  7. Lab Tip #7Lab Tip #7: Why Does pH Matter So Much?
  8. Lab Tip #8Lab Tip #8: What Is Water Activity?

Products

Products in this article

Explore the range

One contact, the whole job

Whatever your laboratory is missing, let us complete it together.

Just tell us what you need. We choose the right product, install it, train your team and stay with you afterwards.

  • Product selection
  • Set-up
  • Training
  • Technical support

Popular: